Glassman High Voltage is a leading designer and manufacturer of High Voltage power supplies/DC power supplies for the High Voltage and Vacuum Process equipment market segments. A Glassman DC power supply can range in output from 15W-50kW with output voltages operating down to 50V thru 400kV.  A High Voltage power supply of this type can be offered in modular or Rack-mount configuration as well as special packaging to meet customer-specific mechanical requirements. Most Glassman DC power supplies are offered utilizing proprietary Air Insulation dielectric technology. Air poses numerous reliability and serviceability benefits in comparison to competing solid and liquid dielectric technologies.
home
about us
products
contact us
technology
opportunities
site map
search
request info
warranty

Glassman HV Catalog

request quote

request short
form catalog

download our
standard catalog

Recent Glassman Ads

 Product Locator:                      

ET Series
2000 Watt Regulated
High Voltage
DC Power Supplies


PDF Print Version

HTML Print Version

ET Series HV Power Supply
Models from 0 to 1kV through 0 to 60kV, 3.5" H x 19" W x 22.0" D, 21 lbs.
Fully compliant with the Following European Directives:
EN61010/ IEC61010, Safety
EN61000-6-4, Conducted and Radiated Emissions
EN61000-6-2:2005, Conducted and Radiated Immunity.
2011/65/EU, Restriction of the use of hazardous substances (RoHS).
  • 1 to 60kV
  • 3.5" Rack Mount Panel
  • CE & Semi S2-93 Compliant
  • RoHS Compliant

The ET Series of 2000 watt high voltage supplies feature flexible embedded controls with low ripple and noise. They are air insulated, fast response units, with tight regulation and extremely low arc discharge currents.

Please refer to Technology > Applications page on our web site for typical applications.

Features Specifications Options Models Outline


Features

Arc Quench. The HV output is inhibited for a short period after each load arc to help extinguish the arc.

Arc Count. Internal circuitry constantly senses and integrates arcs that occur over a given time. In the event a system or load arcing problem develops and exceeds factory-set parameters, the power supply will cycle off in an attempt to clear the fault and then automatically restart after a preset “off dwell time”.

Pulse-Width Modulation. Off-the-line pulse-width modulation provides high efficiency and a reduced parts count for improved reliability.

Embedded Microcontroller Control. Front panel digital encoders provide high resolution local adjustment of voltage and current program. Integral RS-232, USB and optional Ethernet communications provide remote control program and monitor.

Low Ripple. Typically, ripple is less than 0.025% RMS of rated voltage at full load.

Air Insulated. The ET Series features "air" as the primary dielectric medium. No oil or encapsulation is used to impede serviceability or increase weight.

Constant Voltage/Constant Current Operation. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs, and short circuits.

Redundant Thermal Overload Protection. Thermostats and fan RPM sensing shut down the power supply due to over temperature or reduced fan speeds.

Tight Regulation. Voltage regulation is better than 0.005% for allowable line and load variations. Current regulation is better than 0.1% from short circuit to rated voltage.

Constant Current/Current Trip. A rear panel switch allows selection of either current mode.

Slow Start. Adjustable ramp time from 0 - 30 seconds. Output ramps from 0 V to programmed voltage level.

Warranty. Standard power supplies are warranted for three years; OEM and modified power supplies are warranted for one year. A formal warranty statement is available.


Specifications

(Specifications apply from 5% to 100% rated voltage. Operation is guaranteed down to zero voltage with a slight degradation of performance.)

Input: 198 to 264 VRMS single-phase, 48-63 Hz, 4000 VA maximum at full load. C20 connector per IEC 60320 with mating line cord.

Efficiency: Typically greater than 85% at full load.

Output: Continuous, stable adjustment, from 0 to rated voltage or current by panel mounted optical rotary encoder or by external +10V signals. Voltage accuracy is 0.5% of setting + 0.2% of rated. Optical rotary encoder resolution: 0.025% with "Fine Adjustment" mode selected. 0.25% with "Coarse Adjustment" mode (default). Repeatability is < 0.1% of rated.

Static Voltage Regulation: Better than ±0.005% for specified line variations and 0.005% + 1 mV/mA for no load to full load variations.

Dynamic Voltage Regulation: For load transients from 10% to 99% and 99% to 10%, typical deviation is less than 2% of rated output voltage with recovery to within 1% in 500 us and recovery to within 0.1% in 1 ms.

Ripple: Better than 0.025% of rated voltage + 1 V RMS at full load.

Current Regulation: When in current regulation mode, better than 0.1% from short circuit to rated voltage at any load condition.

Voltage Monitor: 0 to +10 V equivalent to 0 to rated voltage. Accuracy: 0.5% of reading + 0.2% of rated. Impedance is 10 KΩ.

Current Monitor: 0 to +10 V equivalent to 0 to rated current. Accuracy: 1% of reading + 0.1% of rated. Impedance is 10 KΩ.

Stability: 0.01% per hour after 1/2 hour warm-up, 0.05% per 8 hours.

Voltage Rise/Decay Time Constant: The voltage rise time constant is 50 ms typical for all models using either HV enable or remote programming control. The voltage decay time constant is 50 ms with a 15% resistive load.

Temperature Coefficient: 0.01% /°C.

Ambient Temperature: -20 to +40° C, operating; -40 to +85° C, storage.

Polarity: Available with either positive, negative, or reversible polarity with respect to chassis ground.

Protection: Automatic current regulation protects against all overloads, including arcs and short circuits. Thermal switches and RPM sensing fans protect against thermal overload. Fuses, surge-limiting resistors, and low energy components provide ultimate protection.

Arc Quench: An arc quench feature provides sensing of each load arc and quickly inhibits the HV output for approximately 20 ms after each arc. Standard on 8 - 60 kV models; optional on 1- 6 kV models.

Arc Count: Internal circuitry senses the number of arcs caused by external load discharges. If the rate of consecutive arcs exceeds approximately one arc per second for five arcs, the supply will turn off for approximately 5 seconds to allow clearance of the fault. After this period the supply will automatically return to the programmed kV value with the rise time constant indicated. If the load fault still exists, the above cycle will repeat. Standard on 8 - 60 kV models; optional on 1- 6 kV models.

External Interlock: Open = off, closed = on. Normally latching except for blank front panel version where it is non-latching.

Remote HV Enable: 0-1.5 V off, 2.5-15 V on.

RS232/USB/Ethernet Programming and Monitor Accuracy:
   Resolution: 0.025% of full scale for both the voltage and the current programs. 0.1% of full scale for both the voltage and the current monitors.
    Remote setting accuracy:
Voltage setting accuracy is better than 0.5% of setting + 0.2% of rated.
    Remote Reading accuracy:
Voltage reading accuracy is 0.5% of reading + 0.2% of rated. Current reading accuracy is 1% of reading + 0.1% of rated.

Rear Panel Elements:

Output Voltage & Current Display: 3.5 Digit digital meters. 1250 count maximum.

Indicators: AC Power, Current Mode, Voltage Mode, Pol +, Pol -, Fault, Fine Adjustment, Preset, Control Lock, Remote Enable, Remote Program, HV On.

AC Power: Rocker switch

Switches (momentary): HV On, SS Slope, Standby, Remote Enable, Remote Program, Preset, Fine Adjust, Control Lock.

Rotary Encoders: Voltage Adjust, Current Adjust.

Rear Panel Elements: AC power entry connector, fuses, power on indicator, ground stud, HV output connector, remote interface connector, RS232/USB connectors, and current trip switch.

The signals provided on the remote interface connector are as follows:

    Inputs: Safety interlock, output voltage and current program signals, high voltage enable and remote HV on.
    Outputs: Output voltage and current monitor signals, HV status, fault status, I/V mode status and a +10 V reference source.

Signal common and ground reference terminals are also provided.

Accessories: Detachable, 8 foot, shielded high voltage coaxial cable (see models chart for cable type), 8 foot NEMA 6-20P line cord, 6 foot NEMA 6-15 line cord, 10 foot null modem cable and 10 foot USB cable are provided.

Weight: Approximately 21 lbs.


Options

Symbol Description
200 200 VAC ± 10%, 48 - 63 Hz.  Derate current by 10%, maximum 1800 W.
NC Blank front panel, power switch only.
ZR Zero start interlock. Voltage control, local or remote, must be at zero before HV will enable.
5VC 0-5 V voltage and current program/monitor.
ARC Arc count and quench as described in the specifications for 1 - 6 kV models.
AC Arc Count Only.
AQ Arc Quench Only.
ETH Virtual RS-232 COM port over Ethernet network. (Requires compatible OS (eg Windows) for COM drivers).
Please consult factory for special requirements.


Models

Click on the model number below to request a quote and for complete ordering part number.

Positive
Polarity
Negative
Polarity
Reversible
Polarity
Output
Voltage
(kV)
Output
Current
(mA)
Max
Stored
Energy
Output
Cable

Reversible
Polarity
Only

ET1R2000 0 - 1kV 0 - 2000mA 1.0 J RG - 58U
ET1.5R1300 0 - 1.5kV 0 - 1300mA 1.9 J RG - 58U
ET2R1000 0 - 2kV 0 - 1000mA 2.4 J RG - 58U
ET3R660 0 - 3kV 0 - 660mA 2.0 J RG - 58U
ET5R400 0 - 5kV 0 - 400mA 2.1 J RG - 58U
ET6R330 0 - 6kV 0 - 330mA 1.4 J RG - 58U
ET8P250 ET8N250 ET8R250 0 - 8kV 0 - 250mA 1.2 J RG - 8U
ET10P200 ET10N200 ET10R200 0 - 10kV 0 - 200mA 1.4 J RG - 8U
ET12P165 ET12N165 ET12R165 0 - 12kV 0 - 165mA 2.0 J RG - 8U
ET15P132 ET15N132 ET15R132 0 - 15kV 0 - 132mA 2.1 J RG - 8U
ET20P100 ET20N100 ET20R100 0 - 20kV 0 - 100mA 2.8 J RG - 8U
ET25P80 ET25N80 ET25R80 0 - 25kV 0 - 80mA 2.9 J RG - 8U
ET30P66 ET30N66 ET30R66 0 - 30kV 0 - 66mA 4.2 J RG - 8U
ET40P50 ET40N50 ET40R50 0 - 40kV 0 - 50mA 4.3 J RG - 8U
ET50P40 ET50N40 ET50R40 0 - 50kV 0 - 40mA 5.3 J RG - 8U
ET60P33 ET60N33 ET60R33 0 - 60kV 0 - 33mA 6.2 J RG - 8U


Outline Drawing