Glassman High Voltage is a leading designer and manufacturer of High Voltage power supplies/DC power supplies for the High Voltage and Vacuum Process equipment market segments. A Glassman DC power supply can range in output from 15W-50kW with output voltages operating down to 50V thru 400kV.  A High Voltage power supply of this type can be offered in modular or Rack-mount configuration as well as special packaging to meet customer-specific mechanical requirements. Most Glassman DC power supplies are offered utilizing proprietary Air Insulation dielectric technology. Air poses numerous reliability and serviceability benefits in comparison to competing solid and liquid dielectric technologies.
home
about us
products
contact us
technology
opportunities
site map
search
request info
warranty

Glassman HV Catalog

request quote

request short
form catalog

download our
standard catalog

Recent Glassman Ads

 Product Locator:                      

ML Series
300 Watt Regulated
High Voltage
DC Modules


PDF Print Version

HTML Print Version

ML Series HV Power Supply
Models from 0-8kVDC through 0-60kVDC; weight <20 lbs.
Fully compliant with the European harmonized EMI directive, EN50082-2, the low voltage (safety) directive, 73/23/EEC and 2011/65/EU, Restriction of the use of hazardous substances (RoHS).
The optional input line active power factor correction reduces harmonic currents below those specified in EN61000-3-2..
  • Medium Power
  • Premium Performance
  • Low Cost
  • RoHS Compliant

The ML Series is a family of sophisticated, medium power, high voltage power supplies that complies with current international safety and EMI directives. We have packaged this series as a space saving module to avoid the expense of front panels and displays. However, no compromises in performance and/or operating features have been made. The result is a power supply that offers outstanding value for a wide range of demanding applications.
Features Specifications Options Models Outline


Features

High Speed Dynamic Voltage Regulation. For load transients of 10% to 99% and 99% to 10%, the output voltage will recover to within 1% in less than 1ms.

Low Ripple. Ripple is less than 0.05% of rated voltage at full load.

Low stored Energy. Most models exhibit less than one joule of stored energy.

Air Insulated. The ML Series features "air" as the primary dielectric medium. No oil or encapsulation is used which would impede serviceability or increase weight.

CV/CC/CT Operation. Automatic crossover from constant-voltage to constant-current regulation provides protection against overloads, arcs, and short circuits. Current mode operation is user configured for constant current regulation or current trip operation.

PFC Option. Assures compliance with EN61000-3-2.

Local Control. User designated ten-turn potentiometer control provides the capability for local control of output voltage or current.

Warranty. Standard power supplies are warranted for three years; OEM and modified power supplies are warranted for one year. A formal warranty statement is available.


Specifications

(Specifications apply from 2% to 100% of rated voltage. Below 2% of rated voltage a slight degradation of ripple, regulation, and stability may occur.)

Input: 90-132VAC single-phase, 48-420Hz, 600VA maximum. Connector per EC 320 with mating line cord terminated with NEMA 5-15 plug.

Efficiency: Typically 85% at full load.

Output: Continuous, stable adjustment, from 0 to rated voltage or current by panel mounted 10-turn potentiometer with 0.05% resolution, or by external 0 to 10V signals is provided. Linearity is < 1% of rated. Accuracy is 0.1% of rated + 0.5% of setting. Repeatability is < 0.1% of rated.

Current limiting/Current Trip: User selectable at interface control connector for either "trip" operation or normal current limiting. If "trip" operation is selected the power supply will latch off in the event the load current exceeds the current "set" point.

Stored Energy: See Models chart. The stored energy includes the capacitance f the standard 8' output cable which is approximately 300pF.

Static Voltage Regulation: Better than 0.005% for specified line and load variations.

Dynamic Voltage Regulation: For load transients from 10% to 99% and 99% to 10%, typical deviation is 2% of output voltage with recovery to within 1% in 1ms, and to 0.1% in 2ms.

Current Regulation: Better than 0.1% of rated current from short circuit to rated voltage at any load condition.

Ripple: <0.05% rms of rated voltage at full load.

Voltage Monitor: 0 to +10V equivalent to 0 to rated voltage. Accuracy, 0.5% of reading + 0.1% of rated. Output impedance is 10 kΩ.

Current Monitor: 0 to +10V equivalent to 0 to rated current. Accuracy, 1% of reading + 0.1% of rated. Output impedance is 10 kΩ.

Stability: 0.01% per hour after 1/2 hour warm-up, 0.05% per 8 hours.

Voltage Rise/Decay Time Constant: 400ms typical with a 5% resistive load using either the HIGH VOLTAGE ENABLE input or remote programming control.

Temperature Coefficient: 0.01% per C.

Ambient Temperature: -20 to +50C, operating; -40 to +85C, storage.

Polarity: Output polarity is available as either positive or negative with respect to chassis ground.

Protection: User selected automatic current regulation or current trip protects against all overloads, including arcs and short circuits. Fuses, surge-limiting resistors, and low energy components provide ultimate protection.

Accessories: Detachable 8' HV coaxial output cable, 6' detachable line cord, and mating control connector.

Interface Control Connector: Twenty-five pin "D" sub-miniature connector. As standard, all ML Series supplies provide output VOLTAGE AND CURRENT PROGRAM/MONITOR (0-+10V = 0-fs), HIGH VOLTAGE ENABLE (0-1.5V off, 2.5 -15V on), HIGH VOLTAGE STATUS (high = HV on, low = HV off), SAFETY INTERLOCK (open = off, closed = on), CURRENT TRIP/ LIMIT select, +10 VOLT REFERENCE source, V/I MODE STATUS (high = voltage mode, low = current mode), LOCAL CONTROL, COMMON and CHASSIS GROUND.


Options

Symbol Description
220 AC input line, rated 180-264VAC, 48-420Hz. Mating line cord terminated with a NEMA 6-15 plug.
SS Slow start ramp. Specify standard times of 5,10,15,20, or 30 Sec, 20%.
5VC 0-5 V voltage and current program/monitor.
PFC Power-Factor Corrected. AC input line, rated 180-264VAC, 48-63Hz, 400VA maximum. Active correction circuitry achieves an input line current harmonic content well below the maximum specified in EN 61000-3-2.


Models

Click on the model number below to request a quote and for complete ordering part number.

Positive
Polarity
Negative
Polarity
Output
Voltage (kV)
Output
Current (mA)
Stored
Energy (J)
Output
Cable
Case
Size
ML08P37.0 ML08N37.0 0 - 8 0 - 37 0.38 RG-8U A
ML10P30.0 ML10N30.0 0 - 10 0 - 30 0.44 RG-8U A
ML12P25.0 ML12N25.0 0 - 12 0 - 25 0.52 RG-8U A
ML15P20.0 ML15N20.0 0 - 15 0 - 20 0.68 RG-8U A
ML20P15.0 ML20N15.0 0 - 20 0 - 15 0.66 RG-8U A
ML25P12.0 ML25N12.0 0 - 25 0 - 12 0.72 RG-8U A
ML30P10.0 ML30N10.0 0 - 30 0 - 10 1.00 RG-8U A
ML40P07.5 ML40N07.5 0 - 40 0 - 7.5 1.44 RG-8U A
ML50P06.0 ML50N06. 0 - 50 0 - 6 1.88 RG-8U B
ML60P05.0 ML60N05. 0 - 60 0 - 5 2.34 RG-8U B


Outline Drawing